Industrial belts served: Makarpura GIDC · Nandesari GIDC · Savli GIDC · Por · Halol · Jambusar
Vadodara is a petrochemical and heavy engineering district, and the tray packages here tend to be large, specification-driven and documented against a named standard rather than quoted off a size list.
Nandesari and the Koyali corridor set the technical bar. Finish is decided per zone, load class and support spacing are checked against the cable schedule, and galvanizing certification is usually part of the submission.
Mitool Equipments Pvt. Ltd. manufactures cable management systems at MIDC Additional Ambernath in Thane district and supplies them throughout Vadodara. We quote against your cable schedule and tray layout rather than a generic size list — send the drawing with the finish required and the quotation comes back with tray sizes, bends, reducers, coupler plates and supports listed line by line, with a dispatch date.
Slotted base that lets cable heat escape and allows clamping and hold-down at any point along the run. The highest-volume tray type on most Vadodara projects.
Open rung construction for the heavy end of the cable schedule — feeds to motors, presses, compressors and switchrooms, on wider support centres.
Bolted rather than welded rungs, so spacing can be reset at site and individual rungs replaced without cutting the run apart.
Supplied in SS304 and SS316 where washdown, process chemistry or chloride exposure rules out a zinc coating.
Wall and structure brackets sized to carry the tray and the cable load above it, in matching material and finish.
The fittings that make a run continuous: bends, risers, reducers, tees, crosses, coupler plates and clamps, all in the tray's own grade.
A starting point for tray selection by application. Final selection follows your cable schedule, fill ratio and support spacing.
| Sector and belt | Typical tray | Usual finish |
|---|---|---|
| Petrochemicals and bulk chemicals Nandesari GIDC, Koyali, Jambusar | Ladder tray for main runs, perforated for instrumentation | SS316 in process areas, hot dip galvanized elsewhere |
| Heavy engineering and power equipment Makarpura GIDC, Savli | Ladder tray for shop power, perforated for control | Hot dip galvanized |
| Automotive Halol, Savli | Ladder tray to presses and paint shops | Pre-galvanized indoors, hot dip for yards |
| Pharmaceutical Por, Savli | Stainless perforated tray in classified areas | SS304; SS316 where process chlorides apply |
| Tank farms and utilities across Vadodara | Ladder tray on outdoor pipe racks | Hot dip galvanized |
Vadodara is a process environment first and a weather environment second. Acid vapour, solvent carry-over and flue gas do more damage to a tray run here than rain ever will, and the finish has to be chosen against the process rather than the climate.
Where the boundaries fall is a Vadodara-specific judgement rather than a general rule. The process zone boundary is the line that matters, and it rarely coincides with a wall. Vapour travels, and the finish should follow the exposure rather than the floor plan. Across a site at Makarpura GIDC, Nandesari GIDC or Jambusar that usually means the tray schedule is split into two or three finish bands rather than quoted at a single grade, and the saving on the lower band normally pays for the upgrade on the higher one.
Hot dip galvanizing to IS 2629 and IS 4759 is the working standard for outdoor racks, utility corridors and tank farms. The heavier coating buys real service life, and it covers welds and cut edges where a formed pre-galvanized section is weakest.
Stainless steel is where the decision actually matters. SS316 is the correct grade inside process areas at Vadodara wherever chlorides or acidic condensate are present; SS304 is reserved for washdown and clean utility areas. This single line item usually drives most of the cost difference between two tray quotations, so it is worth settling with your process engineer rather than defaulting either way.
On Vadodara projects specifically, the runs that get under-specified are the ones crossing a zone boundary — a feed leaving the utility block and entering the process area keeps the utility-block finish all the way through, and fails at the far end first. It is worth walking the route on the drawing zone by zone before the order goes in — on a petrochemicals and bulk chemicalsnandesari gidc, koyali, jambusar job around Makarpura GIDC or Nandesari GIDC, that exercise usually changes two or three line items and costs nothing at enquiry stage.
Powder coating adds little in a chemical atmosphere and can trap condensate against the substrate. Where colour coding of tray runs is required by the plant standard, apply it over hot dip galvanizing, never over bare steel.
| Raw material | Mild steel, stainless steel (SS304 / SS316), aluminium |
| Finish options | Pre-galvanized, hot dip galvanized, powder coated, self-finish |
| Length | 2500 mm – 3000 mm standard; 1000 mm – 3000 mm available |
| Width | 50 mm – 1200 mm (tray); up to 2000 mm on supports |
| Height / side rail | 15 mm – 150 mm |
| Thickness | 1.2 mm – 3 mm |
| Bend | 15 mm – 25 mm |
| Strength class | Light, medium and heavy duty |
| Accessories | Horizontal and vertical bends, reducers, tee and cross sections, coupler plates, clamps, wall mounted supports |
| Supply capacity | 1500 – 2000 metres per week |
| Packing | Loose, nested or in sets as per site requirement |
Tray in India is normally specified to IS 14927 — Part 1 for general requirements, Part 2 for trays and ladder systems including load class and span — with IEC 61537 cited as the international equivalent on multinational projects. Galvanizing is called out as IS 277 for pre-galvanized sheet or IS 2629 and IS 4759 for hot dip. Confirm all three at enquiry stage: standard, load class and support spacing. They have to agree with each other, and settling that before the order costs nothing.
Our works at MIDC Additional Ambernath is about 430 km from Vadodara. Deliveries run to Makarpura GIDC, Nandesari GIDC, Savli GIDC, Por, Halol, Jambusar. Trays are bundled and strapped for site handling, and accessories can be packed separately by zone where a project is erected in phases. For larger site packages we can stage dispatch against your erection schedule rather than delivering the full quantity at once.
Share the tray layout or bill of quantities with sizes, finish and accessories. You get back a line-by-line quotation with dispatch timing.
Request a Quotation Call +91-251-2621925Yes. Our works is at MIDC Additional Ambernath, Thane, about 430 km from Vadodara, and we dispatch to all its industrial belts including Makarpura GIDC, Nandesari GIDC, Savli GIDC, Por, Halol. Trays are supplied in standard 2500 mm and 3000 mm lengths, bundled and strapped for site handling.
Inside process areas where chlorides or acidic condensate are present, SS316 is the correct grade. SS304 is adequate for washdown and clean utility areas. Hot dip galvanized to IS 2629 covers outdoor racks, tank farms and utility corridors, and pre-galvanized should be kept to offices and control rooms.
Zinc corrodes quickly in acidic atmospheres, so a galvanized tray that performs well on an outdoor rack can fail early a short distance away inside a process block. That is why the finish at Vadodara is chosen zone by zone rather than once for the whole plant.
Quantity and finish drive it. Hot dip galvanizing is an extra processing stage after fabrication, and stainless is made to order, so both take longer than pre-galvanized. Share the bill of quantities and the dispatch date is confirmed alongside the quotation.
Yes, against the standard your specification names. IS 14927 Part 2 is the usual Indian reference and IEC 61537 the international one. We need the load class and the support spacing from the drawing as well, because the three have to be consistent.
50 mm to 1200 mm width, 15 mm to 150 mm side rail height, 1.2 mm to 3 mm thickness and 2500 mm or 3000 mm standard length, in light, medium and heavy duty, with supports to 2000 mm. Non-standard sizes are made to order from your drawing.